The company is holder of quality system certificate SK13/2028 in accordance with STN EN ISO 9001:2015.
All the instruments we own are of PFEIFFER VACUUM. The helium leak detector HLT 560 is the most sophisticated. Using this detector controlled by PC, we are able to detect the leaks up to the level of 1,0 x 10E -
13 Pa.m 3/s.
This instrument works in the range from 1,0 x 10E -1 Pa.m 3/s to 1.0 x 10E -13 Pa.m 3/s.
Our employees have excellent practical experience with the leak tests of reactors, heat exchangers, storage tanks, condensers, pipelines etc, especially in nuclear industry.
We are also able to perform the helium leak tests of steam turbines(vacuum part) while in operation. We comply with STN,EN and ASME CODE.
LT/ BC, level 3
LT/ BC, level 2
LT/ B, level 1
VT2; UTT; PT2; RT2; UT2 a MT2
Helium leaktightness test of hermetic cases for spent fuel. All helium leaktightness tests during outages of individual reactor units. Helium leaktightness test of shipping casks for spent fuel and sprinkler system cooler, etc.
Helium leaktightness test of refueling pools. Helium leaktightness and other tests during the outage.
Helium leaktightness tests on various plant equipment.
Helium leaktightness and other tests on new equipment for the A-1 nuclear power plant decommissioning.
Helium leaktightness and other tests on various equipment for the A-1 NPP.
Helium leaktightness test of 131 cases and two new store constructions for spent fuel of the A-1 NPP.
Helium leaktightness test of shipping cask for a rotor.
Helium leaktightness test of storage vessels.
Helium leaktightness test of drainage equipment for spent fuel of the A-1 NPP.
Helium leaktightness test of the sprinkler system cooler for V1 NPP.
Vacuum leaktightness test of high-pressure heaters for a French customer.
Helium leaktightness test of a storage vessel.
Leaktightness test of a large storage vessel.
Helium leaktightness test of reactors No. 1 and 2.
Helium leaktightness test of A1 decontamination line.
Helium leaktightness test of transport piping for acid, etc.
Helium leaktightness test of gas heater, acid cooler E114, etc.
Overpressure leaktightness test of a piping for boat loading in Bratislava port.
Helium leaktightness test of double shell vessels for a German customer.
Helium vacuum leaktightness test of a cold box.
Helium leaktightness test of heating snakes for fermentation tanks.
Helium leaktightness test of steam turbine, valves and flanged connections of the condensate systems.
Helium leaktightness test of welds on large storage tanks using vaccum chambers.
Helium leaktightness test of 220 MW steam turbines at V-1 – 4 off with condensers, connection flanges and valves – under operation.
Helium leaktightness test of steam turbine, connection flanges and valves on the vacuum system EA 129 – Ethylen Management.
Helium leaktightness test of steam 500 MW, 110 MW and 16 MW turbines – condensers, connection flanges and valves.
Helium leaktightness test of double shell vessels for a German customer.
Helium leaktightness test of condenser tubes.
Helium leaktightness test of the steam turbine 110 MW – under operation.
Helium leaktightness test of the steam turbine 25 MW – under operation.
Helium leaktightness test of double shell vessels for a German customer.
Helium leaktightness test of double shell vessels for a German customer.
Helium leaktightness test of condenser tubes.
Helium leaktightness test of condenser tubes.
Helium leaktightness test of condenser tubes.
Helium leaktightness test of condenser tubes.
Helium leaktightness test of condenser tubes.
Leaktightness test of condenser tubes.
Leaktightness test of condenser tubes.
He - TEST, spol. s r.o.
Trstínska 25, 917 01 Trnava
Slovak republic
Business ID: 36218154
VAT: SK2020162023
Tax ID: 2020162023
UniCredit Bank
IBAN: SK87 1111 0000 0066 1822 9007
Mobil: +421 903 404 468
he-test@he-test.sk